Forgot your password? Register
True Decoder Raw Data Record

True Raw Data Record

For a true raw data record according to the |Decoder Communication Protocol please define a custom exporter with the following command:

#[RD_ID];[if([RD_Transponder]<>"";[RD_Transponder];[RD_IDBib])];[([Event.Date]+int([RD_Time]/86400))];[format(([RD_Time]%86400);"hh:mm:ss.kkk")];[if([RD_OrderID]<>0;[RD_OrderID])];[RD_Hits];[RD_RSSI];;[if([RD_ChannelID]>0;1;0)];[RD_ChannelID];[RD_LoopID];[if([RD_StatusFlags]IN"64-127,192-255";1;0)];[RD_WakeupCounter];[([RD_Battery]/10)];[([RD_Temperature]-100)];[RD_StatusFlags];[if([RD_DecoderName]="";[RD_DecoderID];[RD_DecoderName])];;[if([RD_Port]>0;[RD_Port])];[RD_DecoderID]

This expression will deliver passings in the following format:

<PassingNo>;<Bib/TranspCode>;<Date>;<Time>;[<EventID>];<Hits>;<MaxRSSI>;
<InternalData>;<IsActive>;[<Channel>];[<LoopID>];[<LoopOnl<>];[<WakeupCounter>];
[<Battery>];[<Temperature>];[<InternalActiveData>];<BoxName>;<FileNumber>;[<MaxRSSIAntenna>];<BoxId><CrLf>
×

Do you have a question?

Our team is happy to advise you personally.

Contact us!

The team at RACE RESULT will be happy to assess your individual needs, troubleshoot existing issues and answer any questions that you might have. Feel free to reach out through the provided form now.

If you have a support question, please add your event ID!

I have read the data privacy terms.