¿Olvidó su contraseña? Inscripción
Configuration parameter IDs and values/range
Parameter
[parameter-id]

Description

Possible Values
D = Default on startup

[value]

01

Push Pre-warn (non persistent)
Push pre-warn messages prior to real passing

00=disabled (D)
01=enabled

02

Blink/beep on repeated passing (non persistent)
Blink LED on reception of a repeated passing.

00=disabled
01=enabled (D)

03

Impulse input or beep output
Use the headphone jack as impulse input to generate a fake passing.

00=impulse-in
01=beep-out (D)

04

Auto-shutdown on power loss (non persistent)
Switch off the box on power loss. Can be used if timing is finished and you want the USB Timing Box to shut down with the computer.

00=disabled (D)
01=enabled

05

Operation Mode (USB Timing Box only)
usb-kiosk: for testing transponders, showing total number of passings and last transponder ID on the display. CH# and Loop# are automatically set, avoiding any collisions with other r|r Active Systems.
usb-timing: Standard Timing Mode. CH# and Loop# are selected by computer.
usb-store&copy: Transponder will create a stored passing. V2 transponders will send a passing copy to this USB Timing Box.

usb-repeat-impulse: USB Timing Box is in repeat mode. Getting passings is not possible in this mode.

05=usb-kiosk
06=usb-timing (D)
07=usb-store&copy

08=usb-repeat-impulse

06

Channel ID
CH# used for wireless communication. Please note that the channels on the display are shown with an offset of +1, from 1-8.

00 - 07
=> (1 - 8)

07

Loop ID
Loop# of the wire loop. Please note that the IDs on the display are shown with an offset of +1, from 1-8.

00 - 07
=> (1 - 8)

08

Loop Power
Sets the power of the loop, from 0:off to 100:full (hex 64) power.

00 - 64

09

Blink dead-time
Leave set to 15 (hex 0F), don't change!

02 - FF
(default 0F)

0a

Charging via USB
If the timing computer itself is running on battery, it might not be good idea to charge the USB Timing Box.

00:disabled
01:enabled (D)

0b

Use DTR
The DTR line is used for improved timing accuracy, see Timebase Control section.

00:disabled
01:enabled (D)

a0

Tray Scan Power
Sets the power of the loop, from 0:off to 100:full (hex 64) power.

01 - 64
(default 0F)

a1 Tray Scan interval
Time span for which a single row or column is powered.
01 - FF in ticks (1/256th)
(default 50)
a2

Tray Scan ramp up delay
Time to ramp up loop power, before first scan

01 - FF in ticks (1/256th)
(default E0)

a3

Tray Scan row to column delay 
Rows are scanned with scan interval first, then there is a delay, then columns are scanned with scan interval.

01 - FF in ticks (1/256th)
(default E0)
a4

Repeat Row and Column cycle for another N repetitions 
Cycle thru rows 1 + N times.
Cycle thru column 1 + N times.

01 - 0A
(default 00)

b1

Enable CheckSum for all ASCII Protocoll communication (see here)
Only applys to FW 2.5.22868 and up.

0 - 1
(default 0)
b2

Push Passings enable. Only applys to FW 2.6 and up.

Values of 1 and 255 lead to endless pushing of passings

Values > 1 and <= 254 tell the box to push exactly this number of passings. You need to refresh this value again if you want to receive the next passings. 

0 - 1 / 2..254
(default 0)
b3 Enable FW Version 2.6 data reporting format (Signed Temperature, New Beacons Info, Timestamps with 2048th and dayadj) 0 - 1
(default 0)
b4

Enable Status Push Message every second:

#S;[TickCount:8];[MainLoopCycles:4];[LoopStatus:2];[MeasuredLoopPower:2];[ChannelNoise:2];[BattPercent:2]\n\n
#S;015405f2;11f7;00;2c;01;3b\n\n

0 - 1

(default 0)

Parameters 06-08 are stored in a non-volatile memory on power down.

×

¿Tiene alguna pregunta?

Nuestro equipo estará encantado de asesorarle personalmente.

¡Contáctenos!

El equipo de RACE RESULT estará encantado de evaluar sus necesidades, solucionar problemas y responder a cualquier pregunta que pueda tener. No dude en contactarnos a través del formulario.

Si tiene una pregunta de soporte, agregue su ID de evento.

He leído los términos de privacidad de datos .