Command CONFSET

Sets the parameter [parameter-id] to the value [value].

Call

CONFSET;[parameter-id:2];[value:2]\n


Reply

CONFSET;[error-code]\n
[parameter-id:2];[value:2]\n
\n


Example (set loop power to 50%)

← CONFSET;08;32\n
→ CONFSET;00\n
→ 08;32\n
→ \n


Error codes
00 success, no error
10 parameter-id out of range
11 value out of range