Sets the parameter [parameter-id] to the value [value].
Call
CONFSET;[parameter-id:2];[value:2]\n
Reply
CONFSET;[error-code]\n [parameter-id:2];[value:2]\n \n
Example (set loop power to 50%)
← CONFSET;08;32\n → CONFSET;00\n → 08;32\n → \n
Error codes
00 success, no error
10 parameter-id out of range
11 value out of range